G2RL-1A-E2-CV-HA DC12 数据手册
G2RL-1A-E2-CV-HA
PCB Power Relay
G
2
R
L
I
E
2
Compact single pole Relay for
High Current Load Switching &
High Ambient Temperature
• High current 23 A switching surpassing standard G2RL models.
• Meets ambient operating temperature requirements of 105°C
• Low profile; 16.7 mm max. in height.
• Reinforced insulation between coil and contact with 10 kV Impulse voltage.
• Conforms to EN60335-1 of Safety of Household appliances.
• Clearance and creepage distances: 8 mm / 8 mm min.
• Coil insulation system: Class F (UL1446)
G
2
R
L
I
1
A RoHS Compliant
I
E
2 Model Number Legend
I
C
V G2RL- @ @ @-@-@-@
1 2 3 4 5 6
I
H
4. Classification
A 1. Number of pole
Application Examples
• Home appliances
• Cooking top, Microwave Oven
• Industrial use
1: 1 Pole
E2: High-capacity at 23 A
2. Contact Form
A: SPST-NO (1a)
5. Special Requirement
CV: Ambient operating temperature 105°C
3. Enclosure Rating
None: Flux protection
6. Market Code
HA: Home Appliance according to IEC/EN60335-1
• HVAC
Ordering Information
Classification
Contact form
High-capacity &
High-temperature
Enclosure rating
SPST-NO (1a)
Flux protection
Model
Rated coil voltage
Minimum packing unit
G2RL-1A-E2-CV-HA
5 VDC
12 VDC
24 VDC
100 pcs. / tray
Note: 1. When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A-E2-CV-HA DC5
Rated coil voltage
However, the notation of the coil voltage on the product case will be marked as @@VDC.
Note: 2. Place your order in tray (100 pcs./tray) units.
Ratings
●Coil Ratings
Item
Rated current
(mA)
Coil resistance
(Ω)
5 VDC
80.0
62.5
12 VDC
33.3
360
24 VDC
16.7
1,440
Rated voltage
Must-operate voltage
(V)
Must-release voltage
(V)
% of rated voltage
75% max.
10% min.
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note: 2. The operating characteristics are measured at a coil temperature of 23°C.
Note: 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●Contact
Classification
Item
High-capacity & High-temperature type (resistive load)
Model
G2RL-1A-E2-CV-HA
Contact type
Single
Contact material
Ag-Alloy (Cd free)
Rated load
23 A at 250 VAC
Rated carry current
23 A
Max. switching voltage
250 VAC
Max. switching current
23 A
1
Max. voltage (V)
130%
(at 23°C)
Power consumption
(mW)
Approx. 400
G2RL-1A-E2-CV-HA
PCB Power Relay
Characteristics
Classification
Item
High-capacity & High-temperature type
Model
G2RL-1A-E2-CV-HA
Contact resistance *1
100 mΩ max.
Operate time
15 ms max.
Release time
5 ms max.
Insulation resistance *2
1,000 MΩ min.
Dielectric strength
Between coil and contacts
5,000 VAC, 50/60 Hz for 1 min
Between contacts of the
same polarity
1,000 VAC, 50/60 Hz for 1 min
Impulse withstand voltage
Vibration resistance
Shock resistance
Durability
G
2
R
L
I
E
2
10 kV (1.2 × 50 µs)
Destruction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction
1,000 m/s2
Malfunction
Energized: 100 m/s2, De-energized: 100 m/s2
Mechanical
20,000,000 operations (18,000 operation per hour)
Electrical *3
(resistive load)
100,000 operations at 250 VAC, 23 A, at 105°C (1s ON / 9s OFF)
Ambient operating temperature
-40°C to 105°C (with no icing or condensation)
Ambient operating humidity
5% to 85% (with no icing or condensation)
Weight
Approx. 12 g
G
2
R
L
I
1
A
I
E
2
I
C
V
I
H
A
Note: Values in the above table are the initial values at 23°C.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. 360 operations per hour.
Engineering Data
● Ambient Temperature vs. Maximum Coil Voltage
25
Maximum coil voltage (% of rated)
Switching current (A)
● Maximum Switching Capacity
23
20
15
10
5
0
0
50
100
150
200
250
300
200
180
150
130
100
50
0
0
Switching voltage (V)
20 23
40
60
80
100 105 120
Ambient Temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying
range of operating power voltage, not a continuous voltage.
Y
● Ambient Temperature vs.
Must Operate and Must Release Voltage
1,000
X'
1,000
Z
1,000
130
Test conditions: Shock is applied
in ±X, ±Y, and ±Z directions three
times each with without energizing
the Relays to check the number of
malfunctions.
Requirement: None malfuction
100 m/s2
Shock direction
1,000
X
1,000
Z'
Y
1,000
Y'
X
X'
Z
Z'
Unit: m/s2
Maximum coil voltage (% of rated)
● Shock Malfunction
100
Must operate voltage
Must release voltage
90
80
max.
X
min.
70
60
max.
X
min.
50
40
30
20
10
0
0
20
40
60
80
100
120
Ambient Temperature (°C)
Y'
2
G2RL-1A-E2-CV-HA
PCB Power Relay
Dimensions
(Unit: mm)
G2RL-1A-E2-CV-HA
PCB Mounting Holes
(Bottom View)
5
12.7 max.
(12.5)*
29 max.
(28.8)*
G
2
R
L
I
E
2
Six, 1.3-dia. holes
(2.5)
Terminal Arrangement/
Internal Connections
(Bottom View)
1
3
4
8
6
5
7.5
16.7 max.
(16.5)*
(2.3)
0.5
3.5
0.5
(No coil polarity)
20
0.8
0.5
G
2
R Approved Standards
L
(File No. E41643)
I UL Recognized:
1
(File No. LR31928)
A CSA Certified:
I
Model
Contact form
E
G2RL-1A-E2-CV-HA
SPST-NO (1a)
2
I
(Certisfied/No.*****)
C EN/IEC, TÜV:
V
Model
Contact form
I
G2RL-1A-E2-CV-HA
SPST-NO (1a)
H
A
* Average value
Coil ratings
Contact ratings
Number of test operations
5 to 24 V
23 A, 250 VAC (Resistive) 105°C
100,000
Coil ratings
Contact ratings
Number of test operations
5 to 24 V
23 A, 250 VAC (cosφ=1) 105°C
100,000
Creepage distance
8 mm min.
Clearance distance
8 mm min.
Insulation material group
IIIa
Type of insulation coil-contact
open contact circuit
Reinforced
Micro disconnection
Rated insulation voltage
250 V
Pollution degree
3
Rated voltage system
250 V
Over voltage category
III
Category of protection according to IEC61810-1
RTII (flux protection)
Glow wire according to IEC 60335-1
GWT 750°C min. (IEC 60695-2-11/GWFI 850°C min (IEC 60695-2-12)
Tracking Index of relay base
PTI
Flammability class according to UL94
V-0
Coil Insulation system
F Class (UL 1446)
250 V min. (housing parts)
Precautions
●Please refer to PCB Relays Common Precautions for correct use.
Electrical Appliance and Material Safety Law (Japan)
The G2RL-1A-E2 series is not compliant with the Electrical Appliance and Material Safety Law of Japan. Please pay careful attention to
select a suitable relay for the application.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
https://www.components.omron.com/
Asia-Pacific
https://ecb.omron.com.sg/
Korea
https://www.omron-ecb.co.kr/
Europe
http://components.omron.eu/
China
https://www.ecb.omron.com.cn/
Japan
https://www.omron.co.jp/ecb/
© OMRON Corporation 2018 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
3
Cat. No. K315-E1-01
1218(1218)(O)
G2RL-1A-E2-CV-HA DC12 价格&库存
很抱歉,暂时无法提供与“G2RL-1A-E2-CV-HA DC12”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 10+27.69040
- 50+27.02391
- 100+26.37825
- 250+25.74301